AC-DC Switching Power Supply, 2000 Watts, TDMSP-2000 SERIES

  • Universal AC Input (100-240 VAC)
  • Active PFC for EN61000-3-2 Class D Compliance
  • Military Grade
  • Built In DC Fan for Cooling
  • Current Share Function
  • AC & DC Good Signals
  • Remote On/Off & Remote Sense Functions
  • 5V / 0.5A Auxiliary Output Optional
  • 12V / 0.5A Auxiliary Output Optional
Power: 2000W
Voltage: 24 Volts, 28 Volts, 48 Volts
Type: MILITARY GRADE, HIGH POWER, LOW PROFILE, POWER FACTOR CORRECTED
Compare

Description

The TDMSP-2000 Series Power Factor Corrected Military Grade AC-AC Power Supplies provide highly regulated output power up to 2000 watts. Rugged construction and superior quality make these supplies ideal for military and harsh environment applications. TDMSP Military Grade units are available in standard, modified, or fully custom configurations for military applications including airborne, shipboard, and ground mobile platforms. Voltages include 24 Volts, 28 Volts and 48 Volt Models. Please contact us today for a comprehensive price quote.

2000 WATTS
Model #Output VoltageMax. Current
TDRSP-2000-2424vdc80A QUOTE
TDRSP-2000-2828vdc71A QUOTE
TDRSP-2000-4848vdc42A QUOTE

Other voltage and current combinations are available – please contact us for your exact needs.
Input voltage range determines output power.
Note: 2000W @ 190-264 VAC / 1500W @ 100-132 VAC

INPUT SPECIFICATIONS:

Input: Universal AC Input Range 90-264VAC/127-370VDC
Input Frequency: 47-63Hz (400 Hz Optional)
Inrush Current: 25A max at 115VAC/50A at 230 VAC (cold start)
Input Current: 16A max @ 115VAC / 10A max @ 230VAC
Efficiency: 83-90% typical (depending on output model)
Hold-up time: 16ms at full load (minimum)
Leakage Current: <2.0mA maximum @ 240 VAC
Harmonics: EN 61000-3-2, -3 Class D Compliant (0.99 PF Typical)

OUTPUT SPECIFICATIONS

Adjustment Range: ±10% (minimum)
Minimum Load: none
Regulation: line & load ±1%
Ripple/Noise: 150mV peak to peak maximum (20 MHz)
Output Voltage Adj: ±10% minimum
Overcurrent Protection: 105-125% automatic recovery constant current
Overlvoltage Protection: 115-140% of V1 nominal, followed by shutdown
Overtemperature Protection: heatsink temp. 90°C ± 5°C auto-recovery

ENVIRONMENTAL SPECIFICATIONS

Operating Temperature: -25°C to +50°C. Derate to 50% at +70°C
Storage Temperature: -40°C to +85°C max 95% relative humidity
Cooling: Internal ball bearing DC fan
Humidity: 20-90% RH non condensing
Vibration: 10-500Hz, 2G 10 min/1c ycle for 60 min (3 axes)
Shock: 20G peak acceleration – 11 mS half-sine per MIL-STD-810
Weight: ~8.8 lbs.
Size: 13” x 8” x 3”

  • Hot Swap
  • Parallel Operation
  • ORing Diode for Redundant Operation
  • Rack / Panel Mount
  • Ruggedized for Shock & Vibration to MIL-STD-810
  • 400 Hz Operation
  • Conformal Coated PCBs
  • Additional Filtering for MIL-STD-461
  • 5V / 0.5A Aux Output
  • 12V / 0.5A Aux Output

DOWNLOAD PDF DATASHEET