AC-DC Switching Power Supply, 400~1000 Watts, TCD SERIES

  • Rugged Construction
  • Tight Regulation
  • Fully Enclosed
  • MTBF in excess of 150,000 hours
  • OV, OL, OT Protection
  • Low Noise & Ripple
  • Remote On / Off
  • Forced Current Sharing
Power: 400W-1000W
Voltage: 5 Volts, 12 Volts, 15 Volts, 24 Volts, 28 Volts, 48 Volts
Type: RUGGED CONSTRUCTION, HIGH MTBF, ENCLOSED, COTS
Compare Compare

Description

The TCD Series is a compact, high power, single output 400~1000 watt AC-DC switching power supply. This unit is available in 400, 600, 800, and 1000 Watt versions with outputs available in 5 Volts, 12 Volts, 15 Volts, 24 Volts, 28 Volts, and 48 Volts. Robust design makes them ideal for either commercial or harsh environment industrial applications. The TCD Series is also available in ruggedized “COTS” versions for military applications. Please contact us today for a comprehensive price quote.

400 WATTS
Model #Output VoltageMax. Current
TCD-5-805vdc80A QUOTE
TCD-12-3412vdc34A QUOTE
TCD-15-2715vdc27A QUOTE
TCD-24-1724vdc17A QUOTE
TCD-28-1428vdc14A QUOTE
TCD-48-848vdc8A QUOTE
600 WATTS
Model #Output VoltageMax. Current
TCD-5-1005vdc100A QUOTE
TCD-12-5012vdc50A QUOTE
TCD-15-4015vdc40A QUOTE
TCD-24-2524vdc25A QUOTE
TCD-28-2128vdc21A QUOTE
TCD-48-1248vdc12A QUOTE
800 WATTS
Model #Output VoltageMax. Current
TCD-5-1505vdc150A QUOTE
TCD-12-6612vdc66A QUOTE
TCD-15-5315vdc53A QUOTE
TCD-24-3324vdc33A QUOTE
TCD-28-2828vdc28A QUOTE
TCD-48-1648vdc16A QUOTE
1000 WATTS
Model #Output VoltageMax. Current
TCD-12-8312vdc83A QUOTE
TCD-15-6615vdc66A QUOTE
TCD-24-4124vdc41A QUOTE
TCD-28-3528vdc35A QUOTE
TCD-48-2048vdc20A QUOTE

Other voltage and current combinations are available, contact us for your exact needs.

INPUT SPECIFICATIONS:
Input: 90-132/180-264V VAC Switch Select
Input Frequency: 47-63Hz
Inrush Current: 35A/115 VAC, 55A/230 VAC
Input Current: 17.5A / 115 VAC, 10A / 230 VAC
Efficiency: 85 typical (depending on output model)
Leakage Current: <2.5mA maximum @ 240 VAC

OUTPUT SPECIFICATIONS:
Adjustment Range: ±10% (minimum)
Minimum Load: none
Regulation: Line ±0.5% Load ±0.5% Typical
Hold-up time: 20ms/ 230 VAC, 15mS / 115 VAC
Ripple/Noise: 150mV typical peak to peak (20 MHz)
Set Point Accuracy: ±1%(except 5V=±2%) (maximum)
Overcurrent Protection: 105-125% Shut Down, Repower to Recover
Overvoltage Protection: 115-140% Repower to Recover
Overtemperature Protection: Heatsink Temp. 70°C ± 5°C Auto Recovery

ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature: 0°C to +50°C
Storage Temperature: -40°C to +85°C max 95% Relative Humidity
Cooling: DC Fan
Humidity: 20-90% RH non condensing
Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes)(Standard Unit)
Shock: 20G Peak Acceleration (Standard Unit)
Weight: Approx: 5.5 LBS
Size: 2.50” x 5.00” x 11.00”

  • Auto Line Selection
  • 3 Phase Input
  • Parallel Operation
  • ORing Diode for Redundant Operation
  • Rack / Panel Mount
  • Ruggedized for Shock & Vibration
    (MIL-STD-810)
  • 400Hz Operation
  • Conformal Coating
  • LVBD (Battery Back-Up)

Download PDF Datasheet

NEED A QUOTE? Click on the MODELS tab below, then the 'QUOTE' button next to your selected model.