AC-DC Switching Power Supply, 400~1000 Watts, TCD SERIES
- Rugged Construction
- Tight Regulation
- Fully Enclosed
- MTBF in excess of 150,000 hours
- OV, OL, OT Protection
- Low Noise & Ripple
- Remote On / Off
- Forced Current Sharing
- Description
- Models
- Specifications
- Available Options
- Data Sheets
Description
The TCD Series is a compact, high power, single output 400~1000 watt AC-DC switching power supply. This unit is available in 400, 600, 800, and 1000 Watt versions with outputs available in 5 Volts, 12 Volts, 15 Volts, 24 Volts, 28 Volts, and 48 Volts. Robust design makes them ideal for either commercial or harsh environment industrial applications. The TCD Series is also available in ruggedized “COTS” versions for military applications. Please contact us today for a comprehensive price quote.
Model # | Output Voltage | Max. Current | |
---|---|---|---|
TCD-5-80 | 5vdc | 80A | QUOTE |
TCD-12-34 | 12vdc | 34A | QUOTE |
TCD-15-27 | 15vdc | 27A | QUOTE |
TCD-24-17 | 24vdc | 17A | QUOTE |
TCD-28-14 | 28vdc | 14A | QUOTE |
TCD-48-8 | 48vdc | 8A | QUOTE |
Model # | Output Voltage | Max. Current | |
---|---|---|---|
TCD-5-100 | 5vdc | 100A | QUOTE |
TCD-12-50 | 12vdc | 50A | QUOTE |
TCD-15-40 | 15vdc | 40A | QUOTE |
TCD-24-25 | 24vdc | 25A | QUOTE |
TCD-28-21 | 28vdc | 21A | QUOTE |
TCD-48-12 | 48vdc | 12A | QUOTE |
Model # | Output Voltage | Max. Current | |
---|---|---|---|
TCD-5-150 | 5vdc | 150A | QUOTE |
TCD-12-66 | 12vdc | 66A | QUOTE |
TCD-15-53 | 15vdc | 53A | QUOTE |
TCD-24-33 | 24vdc | 33A | QUOTE |
TCD-28-28 | 28vdc | 28A | QUOTE |
TCD-48-16 | 48vdc | 16A | QUOTE |
Model # | Output Voltage | Max. Current | |
---|---|---|---|
TCD-12-83 | 12vdc | 83A | QUOTE |
TCD-15-66 | 15vdc | 66A | QUOTE |
TCD-24-41 | 24vdc | 41A | QUOTE |
TCD-28-35 | 28vdc | 35A | QUOTE |
TCD-48-20 | 48vdc | 20A | QUOTE |
Other voltage and current combinations are available, contact us for your exact needs.
INPUT SPECIFICATIONS:
Input: 90-132/180-264V VAC Switch Select
Input Frequency: 47-63Hz
Inrush Current: 35A/115 VAC, 55A/230 VAC
Input Current: 17.5A / 115 VAC, 10A / 230 VAC
Efficiency: 85 typical (depending on output model)
Leakage Current: <2.5mA maximum @ 240 VAC
OUTPUT SPECIFICATIONS:
Adjustment Range: ±10% (minimum)
Minimum Load: none
Regulation: Line ±0.5% Load ±0.5% Typical
Hold-up time: 20ms/ 230 VAC, 15mS / 115 VAC
Ripple/Noise: 150mV typical peak to peak (20 MHz)
Set Point Accuracy: ±1%(except 5V=±2%) (maximum)
Overcurrent Protection: 105-125% Shut Down, Repower to Recover
Overvoltage Protection: 115-140% Repower to Recover
Overtemperature Protection: Heatsink Temp. 70°C ± 5°C Auto Recovery
ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature: 0°C to +50°C
Storage Temperature: -40°C to +85°C max 95% Relative Humidity
Cooling: DC Fan
Humidity: 20-90% RH non condensing
Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes)(Standard Unit)
Shock: 20G Peak Acceleration (Standard Unit)
Weight: Approx: 5.5 LBS
Size: 2.50” x 5.00” x 11.00”
- Auto Line Selection
- 3 Phase Input
- Parallel Operation
- ORing Diode for Redundant Operation
- Rack / Panel Mount
- Ruggedized for Shock & Vibration
(MIL-STD-810) - 400Hz Operation
- Conformal Coating
- LVBD (Battery Back-Up)