HOT SWAP POWER SUPPLIES – TDRCP-HS SERIES
- (N+1) Redundant, Parallel Operations
- Universal AC Input / Full Range
- Active PFC for EM61000-3-2,-3
- Built in DC Fan for Cooling
- Current Share Function
- AC-DC Good Signal
- Remove ON / OFF & Remote Sense Functions
- 5 V / 0.5 A Auxiliary Output
- Internal Oring Diode
- Description
- Models
- Specifications
- Available Options
- Data Sheets
Description
The TDRCP-HS Hot Swap Rack Mount Power Supply is typically a N+1 design which ensures that full operation of critical loads continue should one module experience an interruption of service. This type of design makes them ideal for Telecom, Data Processing Transportation, Industrial, Military and Commercial applications where critical system operation is a must and no downtime can be tolerated. Hot Swap Systems provides the user the ability to remove and replace a module without compromising system functionality. The TDRCP-HS Hot Swap Power Supply is available in a ruggedized “COTS” version for military applications. Custom configurations and other voltages and power levels are available. Please contact us today for a comprehensive price quote.
Model # With 1000 WATT Modules | Output Voltage | Max. Current | Modules per Rack |
|
---|---|---|---|---|
TD RCP-HS-1000-12 | 12vdc | 60A | QUOTE | 1 |
TD RCP-HS-1000-24 | 24vdc | 40A | QUOTE | 1 |
TD RCP-HS-1000-48 | 48vdc | 21A | QUOTE | 1 |
Model # With 1000 WATT Modules | Output Voltage | Max. Current | Modules per Rack |
|
---|---|---|---|---|
TD RCP-HS-2000-12 | 12vdc | 120A | QUOTE | 2 |
TD RCP-HS-2000-24 | 24vdc | 80A | QUOTE | 2 |
TD RCP-HS-2000-48 | 48vdc | 42A | QUOTE | 2 |
Model # With 1000 WATT Modules | Output Voltage | Max. Current | Modules per Rack |
|
---|---|---|---|---|
TD RCP-HS-3000-12 | 12vdc | 180A | QUOTE | 3 |
TD RCP-HS-3000-24 | 24vdc | 120A | QUOTE | 3 |
TD RCP-HS-3000-48 | 48vdc | 63A | QUOTE | 3 |
Other voltage and current combinations are available, contact us for your exact needs.
INPUT SPECIFICATIONS:
Input: Universal Input Range 100-240 VAC / 127-370 VDC
Input Frequency: 47-63Hz
Inrush Current: 50 A (cold start)
Input Current: 25 A max @ 115VAC 40 A max @ 230VAC
Efficiency: 83-90% typical (depending on output model)
Leakage Current: <1.1 mA maximum @ 240 VAC
Hold-up time: 16ms at full load (minimum)
Harmonics: EN 61000-2-3,-3 Class D Compliant (0.99 PF Typical)
OUTPUT SPECIFICATIONS
Minimum Load: none
Regulation: Line ±0.5% Load ±0.5% Typical
Ripple/Noise: 200 mV peak to peak maximum (20 MHz)
Set Point Accuracy: ± 1% (except 5 V = ± 2%) (maximum)
Output voltage adj: ± 10% minimum (each module)
Overcurrent Protection: 105-125% automatic recovery Constant Current
Overlvoltage Protection: 115-150% of V1 nominal
Overtemperature Protection: Heatsink Temp. 75°C ± 5°C Auto Recovery
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature: -20°C to +50°C. Derate to 50% at +70°C
Storage Temperature: -40°C to +85°C max 95% Relative Humidity
Cooling: Internal ball bearing DC fan
Humidity: 20-90% RH non condensing
Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes)
Shock: 20G Peak Acceleration (Standard Unit)
Weight: Approx: 21 Lbs. (3 module rack)
Size: 14” x 19” x 1.75”
- Battery Back-Up (LVBD)
- Ruggedized for Shock and Vibration
- 400 Hz Operation
- Conformal Coating