The TDRSP-1URK-BBU DC-UPS, Battery Back-Up Power Supply is a compact, self-contained Battery Back-Up System with Power Supply/Charger, Internal High Quality Batteries and Low Voltage Battery Disconnect Circuit. Robust design makes them ideal for Industrial, Military and Commercial applications where critical system operation is a must and no downtime can be tolerated. Extended run times and other output voltages are also available. The TDRSP-1URK-BBU Series is available in a ruggedized “COTS” version for military applications. Please contact us today for a comprehensive price quote.
Model # | Output Voltage | Max. Current | Battery Run Time | |
---|---|---|---|---|
TD RSP-1URK-BBU-12-50 | 12v (13.5v) | 50A | QUOTE | 11 min. |
TD RSP-1URK-BBU-24-25 | 24v (27.6v) | 25A | QUOTE | 11 min. |
TD RSP-1URK-BBU-48-12 | 48v (54v) | 12A | QUOTE | 11 min. |
Model # | Output Voltage | Max. Current | Battery Run Time | |
---|---|---|---|---|
TD RSP-1URK-BBU-12-66 | 12v (13.5v) | 66A | QUOTE | 8 min. |
TD RSP-1URK-BBU-24-33 | 24v (27.6v) | 33A | QUOTE | 8 min. |
TD RSP-1URK-BBU-48-16 | 48v (54v) | 16A | QUOTE | 8 min. |
Model # | Output Voltage | Max. Current | Battery Run Time | |
---|---|---|---|---|
TCP-RK-BBU-24-41 | 24V(27.6V) | 41A | QUOTE | 5 min. |
TCP-RK-BBU-48-20 | 48V(54V) | 20A | QUOTE | 5 min. |
Other voltage and current combinations are available, contact us for your exact needs.
INPUT SPECIFICATIONS:
Input: Universal AC Input Range 90-264VAC
Input Frequency: 47-63Hz (400Hz Optional)
Inrush Cur rent: 25A max at 115VAC/40A at 230 VAC (cold start)
Input Current: 12 A max @ 115VAC 6A max @ 230VAC
Efficiency: 83-90% typical (depending on output model)
Hold-up time: 16ms at full load (minimum)
Leakage Current: <2.0mA maximum @ 240 VAC
Harmonics: EN 61000-3-2, -3 Class D Compliant (0.99 PF Typical)
OUTPUT SPECIFICATIONS
Adjustment Range: ± 10% (minimum)
Minimum Load: none
Regulation: Line±0.5% Load ±0.5%
Ripple/Noise: 150mV peak to peak maximum (20 MHz)
Set Point Accuracy: ± 1%(except 5V=±2%) (maximum)
Output voltage adj: ±10% minimum
Overcurrent Protection: 105-125% automatic recovery Constant Current
Overlvoltage Protection: 115 -140% of V1 nominal
Overtemperature Protection: Heatsink Temp. 90°C ± 5°C Auto Recovery
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature: -20°C to +50°C. Der ate to 50% at +70°C
Storage Temperature: -40°C to + 85°C max 95 % Relative Humidity
Cooling: Internal ball bearing DC fan
Humidity: 20-90% RH non condensing
Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes)
Shock: 20G Peak Acceleration
Weight: Approx: 22 LBS
Size: 1.75” x 19” x 13.5”
- Parallel Operation
- ORing Diode for Redundant Operation
- Digital Meters
- Ruggedized for shock & vibration
- 400Hz Operation