DC-UPS BATTERY BACKUP – TDRSP-1URK-BBU SERIES

  • Universal AC Input/Full range
  • Active PFC for EN61000-3-2,-3
  • Built In Batteries
  • Current Share Function
  • DC Good Signals
  • Remote on/off & Remote Sense Functions
  • Low Voltage Battery Disconnect
Power: 600W-1000W
Voltage: 12V-48V
Type: 1U, LOW HEIGHT, RACK MOUNT, INTERNAL BATTERIES
Compare

Description

The TDRSP-1URK-BBU DC-UPS, Battery Back-Up Power Supply is a compact, self-contained Battery Back-Up System with Power Supply/Charger, Internal High Quality Batteries and Low Voltage Battery Disconnect Circuit. Robust design makes them ideal for Industrial, Military and Commercial applications where critical system operation is a must and no downtime can be tolerated. Extended run times and other output voltages are also available. The TDRSP-1URK-BBU Series is available in a ruggedized “COTS” version for military applications. Please contact us today for a comprehensive price quote.

600 WATTS
Model #Output VoltageMax. CurrentBattery Run Time
TD RSP-1URK-BBU-12-5012v (13.5v)50A QUOTE11 min.
TD RSP-1URK-BBU-24-2524v (27.6v)25A QUOTE11 min.
TD RSP-1URK-BBU-48-1248v (54v)12A QUOTE11 min.
800 WATTS
Model #Output VoltageMax. CurrentBattery Run Time
TD RSP-1URK-BBU-12-6612v (13.5v) 66A QUOTE8 min.
TD RSP-1URK-BBU-24-3324v (27.6v) 33A QUOTE8 min.
TD RSP-1URK-BBU-48-1648v (54v) 16A QUOTE8 min.
1000 WATTS
Model #Output VoltageMax. CurrentBattery Run Time
TCP-RK-BBU-24-4124V(27.6V)41A QUOTE5 min.
TCP-RK-BBU-48-2048V(54V)20A QUOTE5 min.

Other voltage and current combinations are available, contact us for your exact needs.

INPUT SPECIFICATIONS:

Input: Universal AC Input Range 90-264VAC
Input Frequency: 47-63Hz (400Hz Optional)
Inrush Cur rent: 25A max at 115VAC/40A at 230 VAC (cold start)
Input Current: 12 A max @ 115VAC 6A max @ 230VAC
Efficiency: 83-90% typical (depending on output model)
Hold-up time: 16ms at full load (minimum)
Leakage Current: <2.0mA maximum @ 240 VAC
Harmonics: EN 61000-3-2, -3 Class D Compliant (0.99 PF Typical)

OUTPUT SPECIFICATIONS

Adjustment Range: ± 10% (minimum)
Minimum Load: none
Regulation: Line±0.5% Load ±0.5%
Ripple/Noise: 150mV peak to peak maximum (20 MHz)
Set Point Accuracy: ± 1%(except 5V=±2%) (maximum)
Output voltage adj: ±10% minimum
Overcurrent Protection: 105-125% automatic recovery Constant Current
Overlvoltage Protection: 115 -140% of V1 nominal
Overtemperature Protection: Heatsink Temp. 90°C ± 5°C Auto Recovery

ENVIRONMENTAL SPECIFICATIONS

Operating Temperature: -20°C to +50°C. Der ate to 50% at +70°C
Storage Temperature: -40°C to + 85°C max 95 % Relative Humidity
Cooling: Internal ball bearing DC fan
Humidity: 20-90% RH non condensing
Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes)
Shock: 20G Peak Acceleration
Weight: Approx: 22 LBS
Size: 1.75” x 19” x 13.5”

  • Parallel Operation
  • ORing Diode for Redundant Operation
  • Digital Meters
  • Ruggedized for shock & vibration
  • 400Hz Operation
  • Conformal Coating

DOWNLOAD PDF DATASHEET

NEED A QUOTE? Click on the MODELS tab below, then the 'QUOTE' button next to your selected model.